Salt and ice get so cold because salt lets ice keep melting below 32°F, and every pound of melting ice absorbs about 144 BTU from its surroundings. With table salt, the slush chills itself to near -6°F (-21°C).
A Sub-Zero freezer and ice maker use the same physics without salt, which is why the ice maker works slowly.
Why does salt push ice below 32°F?
Salt dissolves into the wet film on ice and forms brine, which stays liquid where fresh water would freeze. Ice touching brine keeps melting, and melting needs heat, so heat leaves the ice, the brine and anything in the bath. Table-salt brine stops falling near -6°F, the coldest point where salt water and ice coexist. Ice cream buckets use rock salt for this reason.
How does a Sub-Zero freezer make cold without salt?
In a Sub-Zero sealed system, refrigerant boiling in the evaporator absorbs heat from freezer air, as melting ice does from brine, and the condenser dumps it into the kitchen. Under the 2017 UL 60335-2-24 standard EPA adopted in 2018, each household refrigerator circuit using R-600a, R-290 or R-441A may hold no more than 150 grams (5.29 ounces); any sealed charge is a technician job, never an owner top-up.
What happens during each ice maker cycle?
A Sub-Zero in-unit ice maker fills its mold, lets freezer air near 0°F pull roughly 144 BTU from every pound of water, then warms the mold briefly to release the cubes. A full bin stops production. Sub-Zero rates them at about 8 cubes (4.6 oz) per harvest every 2-3 hours, or 64-96 cubes per day; an empty bin may take 2 days to fill.
Why does this design produce slow or missing ice?
No cubes on day one: an emptied Sub-Zero ice bin refills slowly by design; wait two harvests.
Small cubes: a short fill into the Sub-Zero mold, from an old filter, a partly closed valve or a pinched line. Sub-Zero requires 20-100 psi or 35 - 120 psi depending on model; a plumber confirms it.
Slow harvests: a Sub-Zero freezer warmer than 0°F removes heat slowly; one that will not hold temperature needs a technician.
An idle UC-15I: Sub-Zero lists 20 psi (1.4 bar) to 80 psi (5.5 bar) and room air of 50°F to 100°F indoors.
How can an owner restart a stalled Sub-Zero ice maker?
Step 1: switch the Sub-Zero ice maker on and clear any cube jamming the bin-full arm or sensor.
Step 2: open the Sub-Zero supply valve fully and replace an overdue filter; a reverse osmosis feed must hold a steady 35 - 120 psi.
Step 3: on a Designer Series undercounter unit, check for a tripped GFCI, which Sub-Zero does not recommend indoors.
Step 4: note the serial tag, on the inside left side wall of UC-15I and DEU1550I units. Sub-Zero Menlo Park Appliance Service lists ice maker and water line work at $290-$880, with the $89 service call waived with repair.